VIDEO OUTPUT CONNECTION
The video output connection is made via a BNC connector on the right side of the unit. The 75 video
output can be looped through typical baseband video inputs of switchers, recorders and other
equipment as required. For proper operation, the output must be terminated with 75. For optimum
performance the video cables should be the shortest length of coax practical.
FIBER CONNECTION
The fiber optic connection is made via a ST connector located on the right side of the unit.
SENSORNET INPUT / OUTPUT CONNECTIONS
Data input and output connections are made via a terminal block on the right side of the unit. Follow
the label on the MRM-61 for proper orientation of Sensornet data input/output wires.
DATA TERMINATION REQUIRMENTS
The MRM-61 is shipped from the factory with internal data input/output 120 ohm termination
switched on. In order to remove the internal termination, the unit needs to be opened up and
switch setting #2 needs to be modified using the internal switch/jumper settings shown below.
There are several other switches on the same switch bank with the data termination switch.
These switches must not be changed. The drawing below indicates their original
positions.
To open the MRM-61, remove the screw on the bottom of the module. Also remove two screws holding
the end panel to the chassis on the side with the video and data connections. Slide PCB assembly out
of chassis to access the switch and jumper locations.